You Searched For: Disinfection+Systems


2,010  results were found

SearchResultCount:"2010"

Sort Results

List View Easy View

Rate These Search Results

Catalog Number: (700-0758)
Supplier: VWR Collection
Description: The PerfectBlue Mini M electrophoresis system is a very convenient size for a wide range of routine uses. Supplied with two combs, but with a wide range of standard and microtitre combs available, this system can be used for the separation of up to 36 samples. The system comes 'ready to use' with lid, power leads and a gel tray. Its high specification construction and embedded platinum electrodes provide high quality results time after time.
UOM: 1 * 1 items


Catalog Number: (700-0880)
Supplier: VWR Collection
Description: Wider than the Maxi S Plus, the Maxi M model can accommodate up to 168 samples but still with an economical footprint.
UOM: 1 * 1 items


Catalog Number: (700-0876)
Supplier: VWR Collection
Description: The smallest of the Maxi series, the Maxi S Plus is suitable for high quality sample separation of up to 160 samples per run. With this flexible system, the gel size can be split into two, three or four sections by using different comb positions, plus the gel size can be reduced using the wall comb or the casting dam system.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: This powerful and intuitive laboratory water purification system produces Type I ultrapure water from RO, distilled or deionised water. The product water quality meets or exceeds CLSI and CAP Type I water standards.

Catalog Number: (700-0777)
Supplier: VWR Collection
Description: Capable of running 12×14 cm gels, the largest of the 'Mini' range still offers the convenience of direct gel casting in the tray, in an easy to manage product size for reliable, high quality electrophoresis. This system can be supplied with a choice of gel trays suitable for 2, 4 or 12 combs, and an expansive range of standard and microtitre combs, making this versatile system appropriate for both routine and small separation electrophoresis.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: For 16×14 cm gels, the Twin M is a versatile system for SDS PAGE applications, in addition to non denaturing electrophoresis of proteins, SSCPs and dinucleotide repeats. With the enlarged upper buffer chamber, water circulation system and heat-sinking aluminium ceramic plates, the Twin M provides high speed separation while maintaining straight, sharp bands.

Supplier: VWR Collection
Description: The PerfectBlue Twin S system is designed for rapid separation of typical 10×10 cm mini gels. Due to its small size and a separation capacity of 6 to 30 samples, it is ideal for fast, analytical separations. A highly efficient cooling system ensures uncompromising results.

Catalog Number: (700-0799)
Supplier: VWR Collection
Description: The 'Revolution' series includes a buffer circulation system, powered by the electrodes themselves. Hydrogen bubbles produced at the cathode pass up a diagonally positioned pipe connected to the two sides of the tank producing a gentle circulation of the buffer. The result is no pH and ionic gradient – without need of mechanical pumps.
UOM: 1 * 1 items


Catalog Number: (700-0842)
Supplier: VWR Collection
Description: With its extra wide design, the Midi ExW is ideal when there is a need to run lots of samples (up to 200) in just a short distance, for example, when genotyping. This format, along with its compact footprint, offers rapid run times without compromising on power. The result is a system for high throughput sample processing, generating crisp clear band data. As with all PerfectBlue gel systems, gels can be poured directly in the trays at temperatures up to +60 °C. With the Midi ExW, the trays can be walled with effective gasketed 'end gates' which are supplied in the system. In addition, gel size can be reduced by using wall combs or the aluminium casting dam.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: Our VWR® laboratory-grade water purification systems feature an inspiring, application-oriented design. Perform your workflows faster and more reliably, simplifying your daily lab work while ensuring cost-efficient operation over the long term. All instruments offer flexible solutions as they can be adapted to your requirements and integrated into your laboratory environment.

Catalog Number: (MFLX01507-87)
Supplier: Avantor Fluid Handling
Description: A complete filtration solution in one unit.
UOM: 1 * 1 items


Supplier: VWR Collection
Description: This compact system produces EDI-based Type II water directly from tap water. Quality of Type II water meets or exceeds water quality as defined by ASTM, CAP, CLSI and ISO 3696 / BS 3997, and also complies with the purified water requirements from the European and U.S. Pharmacopoeia.

Supplier: VWR Collection
Description: This compact 'plug and play' lab water system is an ideal choice for users who need up to 20 litres of ultrapure Type I water or RO water (Type III) per day. Quality of the ultrapure product water meets or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.

Supplier: VWR Collection
Description: This 'two in one' lab water system produces ultrapure (Type I) and RO (Type III) water from tap water. Quality of ultrapure water meets or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.

Supplier: VWR Collection
Description: This powerful, intuitive laboratory water purification system provides superior and consistent ultrapure Type I and EDI-based Type II water from tap water. Water quality meets or exceeds ASTM, CLSI, CAP and ISO Type I water standards, respectively.

Catalog Number: (700-0292)
Supplier: VWR Collection
Description: The shiroGEL mini vertical PAGE system is modular, allowing PAGE and electroblotting to be carried out in the same tank, simply by changing the inserts. The system features inserts for each application, and a common buffer tank in which to run them. Each insert has its own electrode assembly, which connects to the lid of the buffer tank. For safety, the power leads connect directly to the lid. When the lid is removed, power is disconnected from the system. The inserts also have a small pad that fits into position in the lid. This ensures that the lid is always properly placed and aids in its removal. The buffer tank is moulded to prevent separation and leaking. A variety of spacers, combs and other accessories are available to customise the system. All spacers and combs are colour coded or clearly labelled to indicate thickness.
UOM: 1 * 1 items


Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR Regulatory Department at eurega_services@eu.vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organization. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
This product is no longer available. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service at 1-800-932-5000.
81 - 96 of 2,010
no targeter for Bottom