Hexane (mixture of isomers) ≥99.5% (by GC, sum of isomers + methylcyclopentane) (95% n-Hexane), UltimAR® for liquid chromatography, for organic residue analysis, Macron Fine Chemicals™
Supplier: Avantor Performance Materials
|
Danger
|
Synonyms:
Hexanes, Isohexane
H487-10EA
0
INR
H487-10
MACRH487-06
MACRH487-23
Hexane (mixture of isomers) ≥99.5% (by GC, sum of isomers + methylcyclopentane) (95% n-Hexane), UltimAR® for liquid chromatography, for organic residue analysis, Macron Fine Chemicals™
Hexane (mixture of isomers)
Suitable for Liquid Chromatography, Extract/Conc, UV-Spectrophotometry, Organic Residue Analysis
UltimAR®—Solvents that meet ACS specifications for liquid chromatography, UV-spectrophotometry, and general purpose use.
Formula:
H₃C(CH₂)₄CH₃ MW: 86,18 g/mol Boiling Pt: 69 °C (1013 hPa) Melting Pt: –94,3 °C Density: 0,659 g/cm³ (20 °C) Flash Pt: –22 °C Storage Temperature: Ambient |
MDL Number:
MFCD02179311 CAS Number: 110-54-3 EINECS: 203-777-6 UN: 1208 ADR: 3,II Merck Index: 13,04712 |
Specification Test Results
For Laboratory,Research,or Manufacturing Use | — |
methylcyclopentane)(by GC) | ≥99.5 % |
ACS - Assay (sum of 5 isomers, total hexanes plus | ≥99.5 % |
ACS - Assay (as n-hexane) (by GC, corrected for water) | ≥95.0 % |
ACS - Color (APHA) | ≤10 |
ACS - Residue after Evaporation | ≤0.0001 % |
ACS - Sulfur Compounds (as S) | ≤0.005 % |
ACS - Thiophene | Passes Test |
ACS - Water (H₂O)(by Karl Fischer titrn) | ≤0.01 % |
ACS - Water-Soluble Titrable Acid (meq/g) | ≤0.0003 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 195 nm | ≤1.00 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 210 nm | ≤0.20 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 220 nm | ≤0.07 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 230 nm | ≤0.05 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 240 nm | ≤0.04 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 250 nm | ≤0.02 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 254 nm | ≤0.005 |
Ultraviolet Absorbance (1.00-cm cell vs. water) - 280 - 400 nm | ≤0.005 |
Fluorescence Trace Impurities, measured as Quinine Base - at 450 nm Emission | ≤0.3 ppb |
Fluorescence Trace Impurities, measured as Quinine Base - at Emission Maximum for Impurities | ≤1.0 ppb |
ECD Sensitive Impurities (as Heptachl or Epoxide) Single Peak (ng/L) | ≤10 ppb |
FID Sensitive Impurities (as 2-Octano l) Single Peak (µg/L) | ≤5 ppb |
FID - Sum of the Peaks (µg/L) | ≤10 |
ECD-Sensitive Impurities (as Ethylene Dibromide) - Single Impurity Peak (ng/mL) | ≤5 |
Neat Solvent Front Characterization - Largest Peak, 0-0.4 x RT (ng/mL) | |
Filtered through a 0.2 micron filter. | |
Packaged under Nitrogen |