Dichloromethane : Acetone mixture 50 : 50 v/v, ULTRA RESI-ANALYZED®, J.T.Baker®

Supplier: Avantor
Danger


M.O.C. Category NI

9527-4MEA 0 INR
9527-4M 9527-98 9527-99 9527-9E 9527-Q3 9527-V8 9527-XA 9527-Y6 9527-ZY
Dichloromethane : Acetone mixture 50 : 50 v/v, ULTRA RESI-ANALYZED®, J.T.Baker®
Dichloromethane : Acetone mixture
Flash Pt: –20 °C
UN: 1992
ADR: 3, 6.1 II

Order Now

Specification Test Results

For Laboratory,Research,or Manufacturing Use
Acetone - Assay (by GC, corrected for water) ≥99.4 %
Acetone - Color (APHA) ≤10
Acetone - Residue after Evaporation ≤1 ppm
Acetone - Substances Reducing Permanganate Passes Test
Acetone - Titrable Acid (µeq/g) ≤0.3
Acetone - Titrable Base (µeq/g) ≤0.60
Water (H₂O)(by Karl Fischer titrn) ≤0.5 %
Acetone - FID-Sensitive Impurities (as 2-Octanol) Single Impurity Peak (ng/mL) ≤5
Acetone - GC-ECD Sensitive Impurities (as Heptachlor Epoxide) Single Peak (ng/L) ≤10
Methylene Chloride - FID-Sensitive Impurities (as 2-Octanol) Single Impurity Peak (ng/mL) ≤5
Methylene Chloride - GC-ECD Sensitive Impurities (as Heptachlor Epoxide) Single Peak (ng/L) ≤10
Methylene Chloride - Assay (by GC, corrected for water, exclusive of preservative) ≥99.8 %
Methylene Chloride - Color (APHA) ≤10
Methylene Chloride - Residue after Evaporation ≤1.0 ppm
Methylene Chloride - Titrable Acid (µeq/g) ≤0.30
Methylene Chloride - Chloride (Cl) ≤10 ppm
Methylene Chloride - Water (by KF, coulometric) ≤0.02 %